Power supply, Figure 6), 1 power supply – Datalogic Scanning C-BOX 300 User Manual

Page 19

Advertising
background image

INSTALLATION

2

NOTE

Autoconnection is not compatible with Matrix readers and must be
disabled in the C-BOX 3x0 configuration. See par. 2.9 for d
etails.


To disable this automatic connection procedure, refer to WinHost Help Online.

After system functioning has been verified, close the C-BOX 3X0 using the 4 cover
screws making sure the rubber seal is fitted correctly between the parts of the
housing.

2.4.1 Power

Supply


Power is supplied to the C-BOX 3X0 through the pins provided on the spring clamp
connector.

The power switch (see Figure 6) switches the power supply ON or OFF for both the
C-BOX 3X0 and the connected scanner.

ON

OFF

S1

Figure 6 - Power Switch ON/OFF Positions



C-BOX

1

2

VS

GND

USER INTERFACE

GND

V+ (10 - 30 Vdc)

Figure 7 - Power Supply Connections



The power supply must be between 10 and 30 Vdc only.

7

Advertising