Installation – Kemppi Protig 410 User Manual

Page 10

Advertising
background image

EN

20

Earth cable

21

MMA welding cable

22b

Mig gun liquid-cooled

23b

TIG torch, liquid-cooled

23d

TIG extension cable, liquid-cooled

2.

INSTALLATION

2.1

ASSEMBLY OF TIG/MMA EQUIPMENT

Assemble the equipment in below-mentioned order and follow mounting and operation

instructions which are delivered with packages.

2.1.1 Installation of power source

NOTE!

Connection of mains cable and mounting operations as well as change of plug should only

be carried out by a competent electrician.
Read paragraph: ”Installation” in operation instructions (1913130) for Pro power sources and

carry out the installation according to that.

2.1.2 Assembly of transport wagon and mounting of Pro power source to wagon

P20

6185261 air-cooled

TIG

equipment

P30W

6185262 liquid-cooled

TIG

equipment

P40, P40L

6185264, 6185264L

air-cooled TIG equipment

Lifting of wagon together with bottle is forbidden due to safety reasons!

2.1.3 Mounting of Protig 410 unit onto the power source (figure page 5)

NOTE!

Lock the Protig unit carefully as shown in fig. onto pro power source. Loose unit might cause

a danger situation.

2.1.4 Mounting of Protig 410 control panel

TL 6271265

TX 6271266

2.1.5 Connecting cables

Follow enclosed figures:

Air-cooled equipment on page 5

Liquid-cooled equipment on page 6
When connecting cables take into consideration the fact that the most generally used polarity

in TIG welding is the torch - and ground cable +. In MMA welding the polarity is generally

on the contrary (Electrode holder+). Follow instructions as shown on page 5 and 6 when

changing welding method.

2.1.6 Connecting torch and extension cable

Connection to the Protig 410 unit is shown on page 5 (air-cooled torch) and on page 6 (liquid-

cooled torch).
Tighten connector of torch carefully in order to avoid heating, contact disturbances and

mechanical damage of connector as well as gas leakage to inside of connector.

NOTE!

Check by connection of water and gas hoses that there is no dirt, metal powder or other

waste. Waste might cause blockage of water circulation, throughburning of torch, or stopping or

breaking of pump (Procool 10, Procool 30).
Connect water hoses of torch and interconnecting cable as shown in figure on page 6. (These

are fixed to tube frame). Fix water hoses (torch - interconnecting cable - Procool) in such a way

that those having red code always are connected to corresponding red counter connectors

and the blue ones respectively to blue counter connectors.