Operation disturbances – Kemppi Protig 410 User Manual

Page 25

Advertising
background image

EN

7.

OPERATION DISTURBANCES

Error codes

E.1

Not in use

E.2

Bit error in the message content

E.3

Bit error in the end of the message

E.4

Power source doesn´t acknowledge the TIG start

E.5

Conflict of states

E.6

The power source sent message ”error in message”

E.7

EEPROM can´t be programmed

E.8

A message during TIG welding doesn´t get acknowledged

E.9

Error in ”Power source size” information

E.10

Error in ”Power source voltage” information

E.11

Error in momentary voltage information

E.12

Error in message coming from the remote controller

E.13

Error in current information

E.14

Error in version

E.15

”TIG welding stopped” message doesn´t get acknowledged

E.16

”Cooler unit stop” command doesn´t get acknowledged

E.17

”Cooler unit start” command doesn´t get acknowledged

E.18

MMA states in conflict

E.19

Error in voltage information

E.20

Error in MMA set value information

E.21

Waiting for upslope loading (polling)

E.22

Waiting for downslope loading

E.23

Waiting for basic slope loading

E.24

The cooler unit doesn´t answer to start command during welding

E.25

The cooler unit stopped the welding

E.26

Too many bytes in the message

The most usual operation disturbances:

Arc is not ignited:

• Cable is loose or there is a bad connection.

• Electrode of torch is highly oxidized (grey). Sharp again lengthwise. Check that post gas

time is long enough. Check ignition by using pre-gas e.g. by 4-function operation of

torch.

• There are impurities in shielding gas (moisture, air).

• Protective hose of torch is broken and ignition spark is ”escaping” from elsewhere than

from eletrode of torch.

• Torch or extension cable is wet.

• There are leakages due to moisture or dirt in connectors or cables of Protig 410 unit.

• At low current too big or blunt electrode.

• If with operation disturbances there comes to current display continuously error code

in form ”E + number”, take contact with Kemppi service work shop and tell them also

above-mentioned error code.

23

Pr

oT

ig 410 H

yundai / © Kemppi O

y / 1135

Advertising