In panel TX there are also following operation and controls:

Demo: learning and control state
Controls for continuous welding
Controls for pulsed TIG welding
Controls for fusion spot welding
Minilog-function and control of start current
Breaking the down-slope operations
Program storing of selectotig

3.2.1 Control ranges for time and per cent

Pre-gas time

0 – 9 s

Current up-slope time

0 – 9.9 s, 100 ms steps

Start current

30 – 150 %

Minilog basic current

10 – 90 %

Pulse ratio

10 – 80 %

Length of cycle

0,002 – 4 s (max. 500 Hz)

Pause current of pulse

10 – 100%

Spot welding time

0 – 9 s

Current down-slope time

0 – 25.5 s, 100 ms steps

Post gas time

0 – 99 s

Minilog pressing:

short: less than 0,7 s

long: more than 0,7 s

Per cent values of table are calculated from control value.

3.2.2 Demo: Learning and control state

In demo state coming of ignition spark and gas are stopped. All other controls operate as

during welding. Basic controls for current, times and per cent can be carried out safely in this

state and after that you can go over to welding using either spark or contact ignition.
Use arrow keys when you go over to control different functions. You can go to available

controls by selected welding mode. It is indicated by pilot lamp, in which stage of operation
flow chart you are now and which parameters can be controlled by you.