8 Sensor specifications and other sensor information

87

8.7.2 PR-03-W specifications

General specifications

General system specifications for a PR-03-W refractometer sensor

Refractive index range, standard

R.I. 1.3100–1.5400 (corresponds to hot water–100 Conc% b.w.) with
spinel prism

Refractive index range, option

R.I. 1.2600–1.5000 with sapphire prism

Accuracy

R.I. ± 0.0002 (corresponds typically to ± 0.1% by weight).
Repeatability and stability correspond to accuracy.

Speed of response

1.2 s undamped

Damping time constant

Selectable up to 5 min

Process temperature

-20

C–100

C (-4

F–212

F)

Temperature compensation

Automatic

Ambient temperature

max. 45

C (113

F), min. -20

C (-4

F)

Humidity

20–100 %

Pollution degree

Degree 2

Process pressure

max. 10 bar (145 psi)

Recommended flow velocity

1.5–6 m/s

Protected by

US Patent No. US6067151, German Patent No. DE19855218

Sensor
Wetted parts, standard

Teflon

R

PTFE, prism gasket Teflon

R

PTFE, prism spinel or sapphire,

O-ring Kalrez, adaptor sapphire

Sensor weight

With 2” Saunders body 15 kg (33 lbs)/3” Saunders body 26 kg
(57 lbs)/4” Saunders body 33 kg (73 lbs)

Sensor protection class

IP67, Nema 4X

Process connection

With PFA (Fluorinated ethylene propylene) lined Saunders valve body
2", 3" or 4"

Temperature measurement

Built-in Pt-100

Image detector

1024 pixel CCD-element

Light source

Light emitting diode (LED)

Sensor housing

AISI 316L stainless steel cover

Exproof

Exproof by purging

Saunders valve body
Valve body material

Graphite cast iron

Valve body lining material

PFA (Fluorinated ethylene propylene)

Process connection

ANSI flange 4 inch 150 lbs / ANSI flange 3 inch 150 lbs /
ANSI flange 2 inch 150 lbs / DIN flange DN 100 PN 16 /
DIN flange DN 80 PN 16 / DIN flange DN 50 PN 16

Indicating transmitter

See Chapter 9

Options

− External output unit, Section 4.2
− Relay units for alarm, Section 4.1