0 specifications – La Crosse Technology K2-100 User Manual

Page 11

Advertising
background image

GB

GB

GB

36

37

38

37

39

38

40

Timer Mode

-

1 second resolution

Count Down Timer

-

Quick set function (3, 5, 10, 15 and 45 minutes)

-

One user-define timer up to 23 hours 59 minutes 59
seconds


Operation Mode

-

Countdown or repeat mode

Timer Sounds

-

Beep at last 5 seconds and

sounds for 2 seconds when count to zero

Altimeter Mode

-

1m or 3.28ft resolution

Measuring range

-

-702m to 9164m or -2303ft to 30065ft (Assume sea level
is 1013.21 hPa/mbar and 0m)

Display range

-

-9164m to 9164m or

Accuracy

-

+/-50m or +/-164ft (Over temperature range -10.0 C to
60.0 C or 14.0 F to 140.0 F)

-30065ft to 30065ft (Depends on the

altitude reference setting)

Real Time Mode

-

Hour, minute, second, am, pm, month, day, day of week
o r b a r o m e t e r p r e s s u r e t e n d e n c y d i s p l a y ( S e l e c t a b l e
between day of week)

Time System

-

12-hour or 24-hour format

Calendar System

-

Auto-Calendar pre-programmed from the year 2000 to
2099

Alarm Mode

-

1 minute resolution

-

1 daily alarm and 1 date alarm

-

Hourly chime

Alarm Sounds

-

Sounds for 20 seconds at preset time of real time clock

Chronograph Mode

-

1/100 second resolution

Measuring Range

-

23 hours 59 minutes 59.99 seconds

Measuring Mode

-

10 lap memories

-

Recall lap memories and total time

7.0 Specifications

Altitude Reference Setting

-

-9164m to 9164m or -30065ft to 30065ft

Influence

- Minimum influence of temperature change on altitude

Conversion

- ICAO/ISA (Pressure to Altitude conversion)

Sampling Interval

- First 3 minutes: 1 second; after 3 minutes: 1 minute

Barometer Mode

- 0.1 hPa/mbar or 0.01 inHg resolution

Measuring range

- 300.0 hPa/mbar to 1100.0 hPa/mbar or 8.84 inHg to 32.44

inHg

Display range

- Same as measuring range

Pressure Tendency Setting

- 0.01 hPa/mbar resolution

- 0.00 hPa/mbar to 99.99 hPa/mbar

Compensation

- Temperature compensation

7.0 Specifications ...

continue

Sampling Interval

-

First 3 minutes: 1 second; After 3 minutes: 1 minute

Thermometer

-

0.1 C or 0.18 F resolution

Measuring range

-

-10.0 C to 60.0 C or 14.0 F to 140.0 F

Sampling Interval

-

First 3 minutes: 1 second ; After 3 minutes: 1 minute

Backlight

-

Electro-Luminescent (EL) backlight

Battery

-

Single 3V lithium battery (CR2032)

Battery Life

-

Approximately 1.5 year under the following conditions:

30 seconds alarm operation per day

5 seconds EL backlight operation per day

3 minutes sensor mode operation per day

Battery Low Detection

-

Battery voltage< 2.4 V +/- 0.2

Accuracy

-

+/- 1 C or +/-1.8 F (Over temperature range -10.0 C
to +60.0 C or 14.0 F to 140.0 F)