Mixer Reference

Outputs Window

Overload Indicator – Provides instantaneous overload indication of the audio being

played or monitored. Once an overload condition has occurred the overload
indicator remains until reset manually by the user by clicking on the control.

Peak Meters – Displays the instantaneous level of the audio being played or monitored.

Volume Faders – Controls digital attenuation of the audio being played or monitored.

This control acts on the digital signals before D/A conversion. With the volume
fader at its maximum position, the vertical line within the fader turns black, no
volume calculation is performed and the audio stream is unaltered. This is the
recommended position for critical recording and mixdown sessions in which
the highest signal quality is required.
Volume control processing is done prior to
peak meter readings causing the peak meters to reflect any volume control changes.
Since volume changes act on the digitally converted signals, they have no effect
on the analog full-scale input and output levels. This must be done with the Trim
control. When the volume fader is not at its maximum or minimum position, the
vertical line within the fader turns red to indicate that the volume control is active.

Mute – Provides a mute function for each associated output.

Phase – Inverts the phase for each associated output. This is a master control and

overrides the phase controls for any record monitor or play channel assigned to
this output.

Dither – When pressed, enables the addition of triangular probability density dither

for each associated output.