6. Position all butterfly valves as indicated in the

following pictures and in the order as follows:
a. SUMP VALVE - CLOSED
b. SUCTION VALVE - OPEN
c. SPRAY BAR VALVE - CLOSED
d. TANK FILL VALVE - OPEN

7. Ensure water pump and suction hoses are full of

water before operating pump.

Operating the water pump in a dry sump will
result in shaft seal damage.

8. Ensure foot valve remains submerged in water.

9. Start chassis engine.

10. At LOW IDLE turn SYSTEM/POWER switch ON.

11. (DiSCS Only) AUX2 - ON

12. PUMP Switch ON

Engaging/disengaging the water pump above
LOW IDLE may result in water pump component
damage and reduced service life.