POST-WELD Main Setup Screen

Constant Torque Option

This option sets the welder to function in “Melt-Match”
mode, in which the press vertical speed is continuously
adjusted to match the rate of plastic melt at the joint. This
is achieved by measuring the spin torque and changing
the verical speed on-the-fly based on this measurement.
The vertical speed is inversely proportional to the spin
torque: the lower the spin torque, the higher the vertical
speed, and vice versa.
To enable this option, press the

Constant Torque

button

and then the

Enable

box on the screen shown in Figure

5-19. The relationship between the spin torque and
vertical speed is illustrated in Figure 5-20. The welder
will adjust vertical speed for a measured spin torque
along the lines shown. The Torque Target is the desired
spin torque, which is entered into the

Torque (% of max .)

field on the screen. The Max. Torque value is 5% larger
than the Target Torque. If the measured torque exceeds
the Max. Torque, the vertical speed will be 0 until the
torque drops below the maximum. The Max. Speed
is the maximum allowable vertical speed, which will
occur if the measured torque is 0. This value is entered
in the

VERT . Max (mm/s)

field on the

Weld Parameters

screen (in the

WELD

tab). The

Timeout (s)

field specifies

the maximum weld time before the machine aborts the
cycle and reports an error.
The actual spin torque profile achieved during the weld
will depend on the

Torque (% of max .)

and the

VERT .

Max (mm/s)

settings for a particular application. For

example, if the actual spin torque is consistently below
the specified target, the

VERT . Max (mm/s)

will need to

be increased to cause the welder to move down faster,
causing a rise in the spin torque.

POST-WELD Setup

The

POST-WELD

setup is the right tab in the

SETUP

menu and is shown in Figure 5-21. The screen is divided
into two sections:

Hold Setup

and

Part Tests

.

Hold Setup

The

Hold Setup

button is used to enter parameters

related to the Hold phase of the weld cycle. During this
phase, the molten plastic cools and solidifies, beginning
when the spin tool stops. Pressing the

Hold Setup

button

Figure 5–19

Weld Constant Torque Option Screen

Figure 5–20

Graph of Vertical Spin Speed vs . Spin

Torque for Constant Torque Option