Table 9-ii continued – Dukane Dual Servo Spin Welder 403570-01 User Manual

Page 83

Advertising
background image

Dukane Manual Part No. 403-570-01

Page 77

Section 9 - Troubleshooting

Table 9-II continued. . .

Message

Description

Cause

Possible Solution

Spin motor not on

Spin servo amplifier does
not power up

Internal machine error

Contact DUKANE service

Spin servo amplifier faulted

There is a problem with the
spin servo amplifier

1 .

Excessive spin deceleration

2 .

Excessive press weld or hold
speed

3.

Amplifier disabled due to
excessive temperature

4.

Amplifier failed

1 .

Reduce deceleration

2 .

Reduce speed(s)

3 .

a) Reduce machine duty cycle

b) Ensure temperature around
machine is within operational limits

4 .

Contact DUKANE service

Spin servo tracking error

The spin servo motor
was not able to execute
the spinning motion
programmed in the setup

1 .

Excessive press weld or hold
speed(s)

2 .

Excessive spin deceleration

3 .

Joint weld diameter too large

4 .

Improper tuning

1 .

Reduce speed(s)

2 .

Reduce deceleration

3 .

Use welder model with larger spin
torque capability

4 .

Ensure correct tool inertia is entered
in touch screen

Spin weld axis aborted

Expected spin servo move
was not completed

Internal machine error

1 .

Check for obstructions to motion
outside welder

2 .

Contact DUKANE service

Timeout on servo CPU
Thread 1(thrd1)

Motor controller error

Internal machine error

Contact DUKANE service

Timeout on servo response
to command start

Servo system
communication error

Internal machine error

Contact DUKANE service

Vertical at travel limit

Press travel distance
exceeded controller
counting capability

Press travel too large

Reduce weld time / distance / number of
rotations, or hold distance

Vertical motor not on

Vertivcal servo amplifier
does not power up

Internal machine error

Contact DUKANE service

Vertical servo amplifier
faulted

There is a problem with the
vetical servo amplifier

1.

Amplifier disabled due to
excessive temperature

2.

Amplifier failed

1 .

a) Reduce machine duty cycle
b) Ensure temperature around
machine is within operational limits

2 .

Contact DUKANE service

Vertical servo tracking error

The vertical servo actuator
was not able to execute the
press motion programmed
in the setup

Excessive press weld or hold speed Reduce speed(s)

Vertical weld axis aborted

Expected vertical servo
move was not completed

Internal machine error

1 .

Check for obstructions to motion
outside welder

2 .

Contact DUKANE service

Weld trigger position is
below vertical travel lower
limit

Cycle will not start since the
programmed press travel is
larger than the set limit

1 .

Vertical travel lower limit set
too high

2 .

Trigger position too large

1 .

Lower vertical travel lower limit, if
possible .

2 .

Decrease Trigger position

Table 9-II

Machine Display Messages (continued)

Advertising