Part data, Part data list, Clear – Dukane Dual Servo Spin Welder 403570-01 User Manual

Page 74: Write to file

Advertising
background image

Dual Servo Spin Welder User’s Manual

Dukane Manual Part No. 403-570-01

Page 

Figure 8–1

Utility Startup Screen

Part Data

Upon startup, the screen will appear as shown in
Figure 8-1, with the Part Data tab selected by default.
The following is a description of the items on this tab:

PART DATA List

This area contains a series of lines of part data, one
line per part. This data is displayed after each cycle if
the Data Export option in the System Setup screen on
the welder is enabled (See Figure 5-32.). The data is
comma delimited with the fields given in the order as
follows:

1.

Part number (ID)

2.

Test result number

3.

Test result symbol

4.

Date

5.

Time

6.

Weld time (sec.)

7.

Number of weld revolutions

8.

Weld energy (Joules)

9.

Peak spin motor RPM

10.

Peak spin motor torque (% of max.)

11.

Weld orientation (degrees)

12.

Peak vertical thrust (% of max.)

13.

Cycle time (sec.)

14.

Weld end distance (mm)

15.

Hold relative (collapse) distance (mm)

16 . Hold end distance (mm)

CLEAR

Clears parts data from PC screen.

WRITE TO FILE

Writes parts data from the screen to a file on the
computer. After pressing this button, enter the name
of the file where to store the data. Add a .txt or .csv
extension to the end of the file name as the gener-
ated file is in ASCII format. Saving the file with a
.csv extension will allow it to be opened directly
with Microsoft Excel™.