Aasa(data), Aasa(data) -48 – Measurement Computing CB-7080 User Manual

Page 66

Advertising
background image

CB-7080 & CB-7080D Counter/Timer User's Guide

@AASA(data)

2-48

@AASA(data)

Description

: Set alarm limit of counter-1(for alarm-mode 0). Refer to "

Counter alarm mode selection

" for

more information.

Syntax

: @AASA(data)[chk](cr)

@

A delimiter character

AA

2-character HEX module address, from 00 to FF

SA

(data)

8-character HEX value.

[chk]

2-character checksum. If checksum is disabled, no [chk]

(cr)

0x0D

Response

:

Valid response

!AA[chk](cr)

Invalid response

?AA[chk](cr)

no response

Syntax error, communication error or address error

!

A delimiter character indicating a valid response

?

A delimiter character indicating an invalid response

AA

2-character HEX module address

[chk]

2-character checksum. If checksum is disabled, no [chk]

(cr)

0x0D

Examples

:

The alarm limit of counter 1 is FFFF0000h:

command:

@01SAFFFF0000(cr)

response:

!01(cr)

The alarm limit of counter 1 is 0000FFFFh:

command:

@02SA0000FFFF(cr)

response:

!02(cr)

Advertising
This manual is related to the following products: