Installation, Front view, Side view – Montigo H34VO User Manual

Page 5: Top view

Advertising
background image

H-Series VO Outdoor Gas Fireplace

Page 5

XG0150 - 070714

Installation

Section 1: Installation Overview and Product Dimensions

Please review the Installation Checklist on Page 4 for general information

on preparing for a successful installation of your fireplace.
The H-Series VO fireplace may be installed in any location that maintains

proper clearances to air conditioning ducts, electrical wiring and plumbing.

Safety, as well as efficiency of operation, should be considered when

selecting the fireplace location. Try to select a location that does not

interfere with room traffic, has adequate ventilation and offers an

accessible path for Direct Vent installation.

G

H

Top View

F

F

E

J

B

B

D

I

C

D

D

A

A

Front View

G

Side View

P”

N”

Q”

N”

M”

O”

1" clearance

to corners only

Exterior Wall

**Optiona l Drain Pan:

available for all models.

H34VO Part No. OD34123

H38VO Part No. OD38123

H42VO Part No. OD42123

Insulation material

vapor barrier

(exterior wall).

1” Clearance to

combustibles to sides

ot Unit

Figure 1. Fireplace dimensions, (ALL Models, shown in Table on Page 3).

The fireplace dimensions are shown below:

Unit Dimensions

A

B

C

D

E

F

G

H

I

J

H34VO

33⅞" 34⅞" 31⅜" 1¼" 22¾" 5¼" 19¾" 24"

1"

18"

H38VO

37⅞" 37⅜" 35¼" 1¼" 25" 5¼" 20

1

/

16

" 25"

1"

18"

H42VO

42" 41¼" 39½" 1¼" 28¾" 5¼" 21⅝" 28"

1"

18"

Advertising