H-Series VO Outdoor Gas Fireplace

Page 7

XG0150 - 070714

Installation

Clearances

H34VO

With

Insulation

Jacket

H(L)38VO

With

Insulation

Jacket

H42VO

With

Insulation

Jacket

Top

9"

9"

9"

Header

5½"

5½"

5½"

Sides

1"

1"

1"

Floor

0"

0"

0"

Back

1"

1"

1"

Mantel

12"

12"

12"

Ceiling

36"

36"

36"

Figure 3b. Non-combustible surrounds and sidewall clearances.

Figure 3a. Non-combustible facing Material

Finishing Around the Fireplace
All fireplace facing must be non-combustible.
Non-combustible

mantels and mouldings may be safely installed over the top and on the

front of the fireplace provided that they do not project beyond shaded area

shown in Figure 3. Side wall clearances are 3". Only non-combustible

surrounds may be installed around and on the facing of the fireplace

as shown in Figure 3b.

Fireplace Facing
When selecting the finish material for your fireplace, it is important to

remember the following: THE LOWER GAS CONTROL PANEL MUST

NOT BE OBSTRUCTED IN ANY WAY - to do so restricts the air supply

for the control compartments and heat exchanger it also prevents

access for servicing controls.
Decorative facing must not extend past the fireplace opening at all,

because it will interfere with the access to retainers for removal of

glass door.

Figure 3. Non-combustible mantles and facings.

Mantels & Surrounds
NOTE:
National Canadian Gas Association mantel test requirements

are for fire hazard prevention to combustible materials.
New technology, to meet consumer and government demands for the

wise use of energy, has prompted us to manufacture many models of

fireplaces which are hot, fuel and energy efficient.

WARNING:

When this appliance is installed directly on any combustible

material other than wood flooring, it must be installed on a

metal or wood panel extending the full width and depth of

the appliance.

Non combustible

facing

Top of Fireplace

Combustible

Header @ 5½”

5½”

* Shaded area must be non-combustible.

Either Montigo supplied nailing flange, and

cement board or other equivalent

non-combustible material.