H-Series VO Outdoor Gas Fireplace

Page 6

XG0150 - 070714

Installation

Section 2: Framing

Figure 2a. Framing dimensions.

For protection against freezing temperatures, it is recommended that

outer walls of the chase be insulated with a vapour barrier. This will

reduce the possibility of a cold-air convection current on the fireplace.

Choosing The Fireplace Location
The H-Series VO may be installed in an outdoor setting such as a

patio or balcony. Choose a location that maintains proper clearance to

combustibles as noted in the clearances chart.
Note: The H-Serie VO may not be recessed into the exterior wall.

Figure 2. Choosing the fireplace location.

** The H-Series VO models have an Optional Stainless Steel Drain

Pan available. Note, If the Drain Pan is ordered with the fireplace it

must be installed at the time of construction. The Pan cannot be added

at a later date. See Figure 2a above.

Important

If the Optional drain pan is not used during construction; (as shown

in Figure 2a above) ensure any water build-up can escape to the

exterior of the finished enclosure.
Water penetration can occur, and accumulate in the base of the

fireplace, and if not taken into consideration can cause deterioration

of materials, and may cause premature failure of the structure.

G

H

Top View

F

F

E

J

B

B

D

I

C

D

D

A

A

Front View

G

Side View

P”

N”

Q”

N”

M”

O”

1" clearance

to corners only

Exterior Wall

**Optiona l Drain Pan:

available for all models.

H34VO Part No. OD34123

H38VO Part No. OD38123

H42VO Part No. OD42123

Insulation material

vapor barrier

(exterior wall).

1” Clearance to

combustibles to sides

ot Unit

Framing Dimensions

M

N

O

P

Q

H34VO

40⅜" 33⅞" 20¾" 73⅝" 52"

H38VO

43⅜" 37⅞" 21"

79 55⅞

H42VO

46¾" 42" 22⅝" 85" 60"

Clearances

H34VO H38VO H42VO

Mantel

12"

12"

12"

Shelf*

9"

9"

9"

* Dimension plus height of shelf.

Clearances
The H-Series VO clearances to combustible materials are listed below

and are the minimum clearances to combustibles that apply to the

following dimensions:

Figure 3. Minimum Corner framing dimensions.

When installing a shelf over the top of the fireplace, the minimum

clearance from the top of the fireplace to a shelf is 9".
When raising the hearth, the minimum clearance from the top of the

fireplace to a combustible ceiling is 36".

Figure 2b. Framing for shelves over the fireplace.

Warning:
When covering the upper metal portion of the fireplace with a non-

combustible material Please Note: The decorative facing materials

may be subject to temperatures in excess of 250° F. This should be

considered when selecting facing materials.
Please be aware; temperatures over the mantel will rise above normal

room temperature and walls above fireplace may be hot to touch.
We recommend careful consideration be given to the effects of elevated

mantel temperatures which may be in excess of product design, for

example: candles, plastic or pictures.

M

S

9"

N”

M”

O”

**Optiona lD rain Pan:

available for all models.

H34VO Part No. OD34123

H38VO Part No. OD38123

H42VO Part No. OD42123

Insulation material

vapor barrier

(exterior wall).

P”

N”

Q”

1" clearance

to corners only

1” Clearance to

combustibles to sides

ot Unit

Advertising