Installation, Warning – Montigo H34VO User Manual

Page 8

Advertising
background image

H-Series VO Outdoor Gas Fireplace

Page 8

XG0150 - 070714

Installation

Section 4: Wiring

WARNING!

Montigo Part No. #HSIT07 must be encased in a water-tight

electrical box OR ensure the box is installed in a dry location and

avoid any moisture. If installed outdoors, ensure you also install a

Ground Fault Interrupt per local code.

Installing The Remote Switch
The H-Series VO's gas valve, located behind the lower trim, may be

connected to a wall switch. The valve generates its own power on a

millivolt circuit. Use only low voltage wire, and DO NOT connect

any external power to it.
Refer to Figure 4 for wiring requirements.
Note: The switch location must not exceed 30' from the fireplace.

Figure 4. Wiring for the H-Series VO Honeywell gas control and pilot.

Figure 4a. Standing Pilot Diagram

Honeywell (Q3450)

Pilot Assembly

Pilot Electrical

Harness Connector

Honeywell Gas

Control (SV9501M)

Gas Control

Connector

Wall

Switch

Water tight

Electrical box

White

Black

Source 110V

Distribution

Panel

Power
Generator

Wall Switch

Manifold Pressure
Test Connection

Inlet Pressure

Pilot Adjsutment Screw

Advertising
This manual is related to the following products: