FLP4 commands

31

AES-VMUX/-SFP User Manual Rev. G

9 FLP4 commands

FLP stands for Flashlink Protocol. The current revision of this protocol is 4, hence FLP4. This

specification is available from Nevion support.

The following FLP4 block commands are used in the monitoring and control of the module.

• ablk

• ceq

• lsr

• misc

• mtx

• pin

• pwr

• vmon

FLP4 block numbering is 0 based while the display on the webpage and numbering of the physical

connections is 1 based.

9.1 ablk

The ablk blocks list the AES port direction and signal sampling frequency.

Inputs report AES input signal presence.

Outputs report signal presence on the routed timeslot.

9.2 ceq

The cable equaliser block reports signal presence on the electrical input.

9.3 misc

The misc block has several keywords reporting the following:-

• the programming state of the module where ’fin’ indicates a successful programming.

• ovr is the Card Mode where configuratiuon is not allowed form GYDA.

• the locating state where the front LEDs flash. The keyword ’locating’ is followed by the

number of seconds of locating state remaining.