Block Blk

#

Commands

Example

Response

Control

above.

-

-

chk off

chk off

ok

Checksum off
If issued twice in succession, this
command will disable checksums.
Note: Responses will still have the
checksums appended.
NOTE1:? command turns the
checksum on again

-

-

locate on <seconds>

locate off

locate on 3

locate off

ok

Card locator
This command will cause all the
LEDs to flash for a user specified
number of seconds. If omitted, the
value <seconds> will be set to a
default of 120 seconds. The flashing
can be terminated at any time with
locate off.

-

-

address

address

address <address> Card address

This command will force the module
to check and update its current rack
and slot address. This is normally
only done at start-up.

-

-

filename

filename dwchddmux-
0-105.ffw

<name>'.'<extensio
n>

Firmware update
The <name> part must match the
card's hardware and include a
revision number, and the extension
must be either 'ffw' for FPGA
firmware or 'mfw' for microcontroller
firmware. After running this command
the board will be ready to receive its
new firmware in Intel-hex format.

-

-

fin

fin

ok

Finalize
Finalize the programming of the
microcontroller. See description of
the uC boot loader (separate
document).

misc

0

-

NOT AVAILABLE BY
COMMAND.
ONLY FOUND in conf
0

prog | fin

' ' | ovr

Misc info
prog if the card is freshly
programmed by the boot loader and
the program is still un-finalized. fin is
the normal condition.
ovr if DIP-switch 16 is set to the ON
position and the card is under DIP-
switch control.
Note 1: The info part of misc has
additional functionality when locate is
used: locating <remaining seconds>.
This enables a visible countdown
clock in Gyda, but is not a required
part of FLP400.