3 commands intended for debug/lab use only, Dwc-hd-dmux rev. f – Nevion DWC-HD-DMUX User Manual

Page 30

Advertising
background image

DWC-HD-DMUX

Rev. F


nevion.com | 30

Block Blk

#

Commands

Example

Response

Control

957cBu, 247cBu], representing the
range [-95.5dBu, 24.5dBu].

uart

0

-

tx

The embedded data link, selectable
by cho 13. No control possible, the
word tx indicates that this is a
transceiver only.
Uart info reports link status: los (loss
of signal), raw, or the speed of the
embedded link (example:
115200/8/n/1).

6.2.3 Commands intended for debug/lab use only

Block Blk

#

Commands

example

Response

Control

spir

-

<address>

spir 0x0004

Read a single word (or byte) from a
SPI registers to check register status.
Addressing is 16b and most
significant nibble determines which
chip. These are the address ranges:
0x0000

– 0x0fff : audio DAC

0x1000

– 0x1fff : FPGA

0x2000

– 0x2fff : flash

0x3000

– 0x3fff : deserializer

0x4000

– 0x4fff : serializer

0x5000

– 0x5fff : shift register (for

LEDs)
0x6000

– 0x7fff : video DAC

Note: The video DAC is actually
using I2C, but the addresses are
mapped into the SPI address range.

spiw

-

<address> <data>

spiw 0x0004 0x2c

With the same address ranges as for
spir above, this command allows
single SPI registers to be modified.
Modifying SPI registers in the flash
area is strongly discouraged!