Nortec HP Series User Manual

Page 43

Advertising
background image

HP Series Installation Manual | 40

4 Changing Oil:

Identify your pump from the figures on the adjacent page.

Remove the oil fill cap and the oil drain plug(s).

Dispose of spent oil as per local regulations.

Reinstall the drain plug(s). Torque to 18 lb-ft (hand tight). Do not over tighten.

Add recommended amount of oil to crankcase. Refer to the chart below for oil capacities.
Ensure that oil reaches the center of sight glass. Do not overfill.

Reinstall the oil fill cap.

Press the reset rocker switch inside the pump controller to reset the counter and shutoff the
service indicator.

Table 3: Crankcase Oil Capacity

Pump Model

Oil Capacity - Do Not Overfill

Giant P205REIB

9 fl. oz

Giant P208REIB

9 fl. oz

Giant P217REIB

9 fl. oz

Giant P218REIB

9 fl. oz

Giant P219REIB

9 fl. oz

Giant P220REIB

9 fl. oz

Giant P56W

14 fl. oz

Giant P420A

30 fl. oz

- Synthetic 75w-90 grade oil is recommended for all applications (Mobile1 or equivalent).
- Synthetic 15w-50 grade oil can be used as an alternate grade. (Mobile1 or equivalent).
- All labels on pump supersede this manual.

Incorrect oil grades can cause pump damage. Damage resulting from incorrect oil grades is
considered misuse and is not covered by warranty.

Advertising