OWON HDS Series User Manual

Page 58

Advertising
background image

OWON HDS Series Handheld DSO & DMM

8-Advanced Function of Oscilloscope

CH2

Measure the

+Duty

of CH2

-Duty

CH1
CH2

Measure the

-Duty

of CH1

Measure the

-Duty

of CH2

DelayA B

CH1
CH2

Measure the

DelayA B

of CH1

Measure the

DelayA B

of CH2

DelayA B

CH1
CH2

Measure the

DelayA B

of CH1

Measure the

DelayA B

of CH2

To measure the frequency of CH1 with Measurement 1 and the peak-to-peak of CH2 with
Measurement 2, do the following:

1. Press

the

MENU key and the function menu is shown at the right of the screen.

2. Press

the

MENU ▲ or MENU ▼ key to select Measurement 1. Five options appear at the

bottom of the screen.

3. Press

the

F1 key to select the frequency measurement as CH1. The measurement window 1

on the screen turns into one red in color and shows the frequency of CH1.

4. Press

the

MENU ▲ or MENU ▼ key to select Measurement 2. Five options appear at the

bottom of the screen.

5. Press

the

F4 key to jump to the peak-to-peak measurement as CH2. The measurement

window on the screen turns into one blue in color and shows the peak-to-peak value of
CH2.

Now, you can see a screen that looks like the following figure 49.

figure 49: Automatic Measurements

Term interpretation
Vpp
: Peak-to-Peak Voltage.
Vmax: The maximum amplitude. The most positive peak voltage measured over the
entire waveform.
Vmin: The minimum amplitude. The most negative peak voltage measured over the
entire waveform.

50