INSTALLATION & CONNECTION

QC40198 User Manual

20 |

P a g e

3.7.2 Alarm Input Port

Refer to the following sheet for more information.

 Normal open or Normal close type
 Parallel connect COM end and GND end of the alarm detector (Provide external power to the alarm detector).
 Parallel connect the Ground of the combo DVR and the ground of the alarm detector.
 Connect the NC port of the alarm sensor to the combo DVR alarm input (ALARM)
 Use the same ground with that of combo DVR if you use external power to the alarm device.

Figure 3-8

3.7.3 Alarm Output Port

 3 way relay alarm output (NO contact). Provides external power to external alarm device.
 To avoid overloading, please read the following relay parameters sheet carefully.
 RS485 A/B cable is for the A/B cable of the PTZ camera.

Relay Specification

Model:

JRC-27F

Material of the
contact

Silver

Rating(Resistance

Load)

Rated switch capacity

30VDC 2A, 125VAC 1A

Maximum switch power

125VA 160W

Maximum switch voltage

250VAC, 220VDC

Maximum switch currency

1A

Insulation

Between contacts with same
polarity

1000VAC 1minute

Between contacts with
different polarity

1000VAC 1minute