4 loop detector wiring, Reverse, Reverse automatic exit shadow – DoorKing 6500 User Manual

Page 19

Advertising
background image

17

Automatic exit loop
lead in wires are
twisted approx. 6
twists per foot.

Reverse loop lead in
wires are twisted
approx. 6 twists per
foot and are wired in
series.

Shadow loop lead in
wires are twisted
approx. 6 twists per
foot.

20

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

Reverse

Reverse

Automatic Exit

Shadow

2.4 Loop Detector Wiring

•

If other detectors are used, use a separate power

supply to power these detectors.

•

Loop layout shown is for a typical swing gate

application with two-way traffic, or one-way exit
only

traffic.

•

Refer to the Loop Information Manual (available

from

www.dkaccess.com

) for more information

on loops and loop detectors.

Loops and loop detectors MUST be installed with this gate
operator to help prevent the gate from accidentally closing
on vehicular traffic.

•

Loop detector wiring is shown for DoorKing plug-in loop

detectors only. If other loop detectors are used, refer to
the installation instructions supplied with those detectors
for wiring instructions.

Com

9410

9409

N.O.

11

ON

2

3

4

5

6

7

8

SW 1

Note: SW 1,
switches 5,
7 and 8
must be
OFF.

Note: Relay
must be set
to N.O.

Shadow Loop Output

NC

NO

6500-065-K-7-08

Advertising