Reverse sensor – DoorKing 6500 User Manual

Page 24

Advertising
background image

22

6500-065-K-7-08

3.1 Circuit Board Adjustments

SECTION 3 - ADJUSTMENTS

The switch settings and adjustments in this chapter should be made after your installation and wiring to the operator(s) is
complete. Whenever any of the programming switches on the circuit board are changed, power must be shut-off, and then
turned back on for the new setting to take effect.

20

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

Auto close timer

(when turned on)
SW 1, switch 4.

Adjust from 1
second (full
counter clockwise)
to approximately
23 seconds (full
clockwise).

Dry relay contacts

(terminals 10-11) can be
set for Normally Open
(NO) or Normally Closed
(NC) operation by placing
the relay shorting bar on
the N.O. or N.C. pins
respectively.

Self test mode is for
bench checks only.
The operator will
continually cycle the
gate.

The jumper must be
set at normal mode
to function.

Set the DIP-switches on the

circuit board to the desired
setting. See switch-setting
charts on next page.

1

ON

2

3

4

5

6

7

8

1

ON

2

3

4

5

6

7

8

N.

C.

N.O.

SW 1

SW 1

Self Test

Mode

Normal

Mode

1

ON

2

3

4

SW 2

Loop Detector

Loop Detector

1

23

9410

EXIT

SHADOW

SHADOW OUTPUT

REVERSE

9409

Self Test

Auto Close Timer

DIP-Switches

Dry Relay Contact

Adjust reversing sensitivity

for PRIMARY (single) and
SECONDARY (dual) operators.

Min

Max

Secondary

Primary

Min

Max

Reverse Sensor

Advertising