SECTION 5 - OPTIONAL CONVENIENCE OPEN ADJUSTMENTS

The optional convenience open system installed in your vehicular gate operator is designed as a convenience enhancement only.
It is not designed or intended to provide continuous gate operation during a power outage. Its sole purpose is to provide a
method to open the vehicular gate to allow unimpeded traffic flow when the gate and access control system is without power. If
your access control system requires 100% power backup and continuous operation when primary (AC) power has failed, a
power inverter / backup system, such as DoorKing’s Model 2000, is required.

The convenience open system cannot provide continuous gate operation during a power outage.

This system cycles the gate to the open position one time only after AC power failure.

The convenience open system requires testing on a monthly basis to insure the batteries are fully charged and that the

system is operational.

The convenience open system uses two 12-volt, 3.0 amp-hour gel-cell batteries. These batteries should be replaced

every two years on average, or sooner if required.

Batteries are affected by temperature. Cold temperatures will reduce the effectiveness of the batteries. High temperatures

will result in a shortened battery life.

Batteries are not covered under warranty.

This convenience open system consist of a control board (2340-010), motor and power supply (batteries) providing a
completely redundant drive system to open the gate should a power outage occur. This system is not designed to maintain
continuous gate operation; rather it provides a convenient method to open a gate ONCE during adverse conditions. If continu-
ous gate and access control system operation is required, refer to the DoorKing Model 2000 Inverter / Backup Power System.

5.1 Operating Mode

Turn switch 1 ON and the system will automatically
open the gate approximately 3 seconds after loss of
AC power. Automatic mode is always used for for
gates in general access applications such as gated
communities, apartment complexes, etc.
Switch 1 OFF is not used.

Automatic Open after loss of AC Power

Once AC power is restored, the system’s control board
can be set to “automatically re-key” the gate operator
(switch 3 ON) to establish normal operation, or can be
set to require a “manual input” (switch 3 OFF) before
the operator resumes normal operation.

Restart Options once AC Power is restored

DIP-Switches

DIP-Switches