2.6 Primary / Secondary (Dual) Gate Connection

1

Motor

2

Motor

3

Neutral

4

24V

A

C

5

Limit

6

Spare

7

Limit

8

COM

1

Motor

2

Motor

3

Neutral

4

24V

A

C

5

Limit

6

Spare

7

Limit

8

COM

Conduit

Primary/secondary
interconnection cable
in underground conduit.

AC Power Conduit to
Primary Operator Only.

Secondary Operator Terminal

Conduit

Primary Operator Second Terminal

Primary Operator

Secondary Operator

Primary Operator Control Board

Connect the Primary / Secondary interconnection wiring as shown. Wire colors are based on
DoorKing interconnection cable (P/N 2600-75x). Power is supplied to the secondary operator
by the interconnection cable.

Secondary operator contains NO control board.

All control, loop detector, safety and auxiliary

devices are wired to the primary operator.

Operator
Chassis
Ground

Operator
Chassis
Ground

20

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

(Red) Motor 1

(Blue) Motor 2

(White) Neutral 3

(Purple) 24VAC 4

(Yellow) Limit 5

(Brown) Spare 6
(Orange) Limit 7

(Gray) COM 8

Motor 1 (Red)
Motor 2 (Blue)
Neutral 3 (White)
24VAC 4 (Purple)
Limit 5 (Yellow)
Spare 6 (Brown)
Limit 7 (Orange)
COM 8 (Gray)

Secondary Operator

Primary Operator

Interconnection Cable Wiring

Prima

ry/Secondar

y Inter

connection Cabl

e

6500-065-K-7-08