3 dip-switch settings 5.2 dc system description, Switch function setting description – DoorKing 6500 User Manual

Page 32

Advertising
background image

30

6500-065-K-7-08

DC MOTOR NEGA

TIVE OUTPUT

DC MOTOR POSITIVE OUTPUT

BA
TTER

Y NEGA

TIVE INPUT

BA
TTER

Y POSITIVE INPUT

24 V

AC COMMON

24 V

AC INPUT

ACTIV

A

TION OUTPUT

RADIO POWER Not used.

OPEN INPUT

COMMON Not used.

5.3 DIP-Switch Settings

5.2 DC System Description

Switch

Function

Setting

Description

Operation

Changes

Open Direction

Automatic

Power-up

Activation

OFF

ON

ON

OFF
OFF
OFF
OFF

Operator Type

Not Used

Not Used

Not Used

Do Not Adjust

Do Not Adjust

Timer Not Used

Charging LED

Orange to Second Terminal #5

Not Used
Not Used

1

2

3

4

5

6

7

8

Gate will automatically open when a power outage occurs.

Set so that the gate cycles to the open direction upon loss of AC power.

OFF

ON

OFF

When AC power is restored, an input (push button, loop, radio receiver, etc.) is
required to return the gate to normal operation.
When AC power is restored, a 1-second pulse is sent to the gate operator input to
automatically restore normal operation.

Must be in the ON position.

2340

DIP-Switches

Gate will automatically OPEN and stay open
during an AC power failure. DIP-Switch 3
setting will determine how operator will
return to normal operation once AC power
has been restored.

+

12 V

3 Amp/Hr

+

12 V

3 Amp/Hr

Batteries

To Secondary Operator

DC ON/OFF

Power Switch

Red

Black

Red/White

Red/White

DC Motor

Black/White

Green not used.

Purple to Second Terminal #8

White to Second Terminal #7

Diode

Orange to P2 Plug on Circuit Board

To Primary or Single Operator

Green to Main Terminal #5

Purple to Main Terminal #3

White to Main Terminal #13