Remko etf 400, Commissioning – REMKO ETF 400 User Manual

Page 10

Advertising
background image

Starting the unit

1. Move the operating

switch [2] to the "0"
(off) position.

2. Connect unit

mains plug
to a properly
installed
and protected
mains socket
230V/ 50 Hz
.

3. Move the operating

switch [2] to the "0"
(off) position.

4. The green control lamp"

in operation" will illuminate
and the unit will operate in fully-
automatic dehumidification
mode.

Before commissioning the unit
or if local requirements dictate,
the air-inlet grille and air-outlet
grille must be checked for
contamination.

Important points
prior to installation

All extensions to the electrical

connection must
be of a sufficient cable size
and must only be used fully
rolled out or unrolled

Never use the mains cable

asa pull cord

After being switched on,

the units operate fully-
automatically until switched
off by the float when
the condensate container is full

The condensate container

must be inserted properly
and the sealing flap must be
locked

Commissioning

Operation and gauge

1

2

3

4

1 = Operating hours counter

2 = Operating switch

3 = Control lamp -GREEN-

"In operation"

4 = Control lamp -YELLOW-

"Container full"

Operation with a humidity
switch

The REMKO humidity switch
(accessories) is supplied with
a special adapter.

The following procedure must
be followed when commissioning
units in conjunction with
a humidity switch:

1. Insert the adapter into

a properly secured mains socket.

2. Place the humidity switch

in a suitable location within
the room being dehumidified.
Not in the immediate vicinity
of the units or sources of heat.

3. Insert the mains plug (or a cable

extension) into the adapter.

4. Set the desired air humidity

on the humidity switch.

5. Move the operating switch [2]

on the unit to position "I".

The units will switch
on automatically when the air
humidity in the room exceeds
the pre-set level on the humidity
switch.


The units will now operate fully-
automatically until the desired
relative humidity (% RH) has
been reached or until the unit
is switched off by the float when
the condensate container is full.
In the event that this occurs,
the yellow "Container full" control
lamp will illuminate.

NOTE

A contaminated grille or filter
must be cleaned or replaced
immediately.

NOTE

In room temperatures below

10°C

and relative humidity

below

40%

, economical

use of the unit can no longer
be guaranteed.

NOTE

The units are only
functional when operated with
a correctly inserted condensate
container.

10

REMKO ETF 400