Set-up – REMKO ETF 400 User Manual

Page 9

Advertising
background image

Electrical connection

■

The units are

operated
with 230 V / 50 Hz
alternating current.

■

The electrical connection

is made using a built-in mains
cable with earthed safety plug

■

Extensions to the connection

cable may only be carried out
by authorised electricians,
subject to the length
of the cable, connected load
of the unit and taking into
consideration how the unit
is used at its location

Set-up

For the best economic and safe use
of the units, the following notes
must be followed in full:

■

The units must be set

up in an upright and level
position, so as to ensure
unobstructed flow
of the condensate

■

To ensure optimum air

circulation, the units should
be set up in the centre
of the room, where possible

■

It must be ensured that the air

can be sucked in on the front
of the unit and blown out
of the rear of the unit without
obstruction

■

Observe a minimum clearance

of 50cm from walls at all times

■

Units must never be set

up in the immediate vicinity
of heaters or other sources
of heat

■

Air circulation is improved

if the unit is set up approx. 1 m
above the ground

■

The room being dried

or dehumidified must be closed
to the neighbouring atmosphere

■

Avoid having opened windows

and doors etc., and avoid
frequent entry to or exit from
the room as much as possible

■

If the units are to be used

in dusty environments
or stables, appropriate care
and maintenance measures
should be taken according
to therelevant conditions

■

The output of the unit is entirely

dependent on the conditions
inside the room, room
temperature, relative humidity
and observance of the set-up
instructions

NOTE

The electrical connection

to the units must be made

at feedpoints with residual

current devices in accordance

with VDE 0100, Section 704.
When installing the units

in extremely damp

environments such as laundry

rooms, showers etc.,

the customer must ensure

that the unit is secured

with a residual current

device in accordance with

the regulations.

Wall clearance
min. 0.5 m

Maintain adequate clearance from

heaters or other sources of heat.

Keep windows and doors closed!

ATTENTION

All cable extensions must
only be used in a rolled out
or unrolled state.

!

9