Cleaning the units

The unit housing must be opened
to allow the inside of the unit
to be cleaned and to provide
access to electrical components.

1. Remove the mains plug from
the mains socket.

2. Dismantle the transportation
bracket (A) and the stand (B)
by removing the 4 threaded
bolts.

3. Dismantle both side covering

panels (C).
To do this, loosen each
self-tapping screw from
the underside, slide the panel
downwards towards the wheel
and then upwards out of the
mount.
Remove the conductor on
the inside of the panel.

Cleaning the dust filter

Slide the protective grille upwards
slightly, then pull forwards and
remove downwards.

Then remove the dust filter which
has now been released.

Light contamination of the dust
filter may be remedied with careful
blowing or suction.

Heavier contamination may
be remedied by rinsing the filter
in a lukewarm (max 40°C) soap
solution.

Finally, always ensure to rinse
the filter carefully with clear water
and allow to dry.

Before refitting the dust filter,
ensure that its fully dry and that
no damage has been sustained.

The units may only be operated
with the dust filter in place.

Observe the regular care

and maintenance intervals

In accordance with theoperating

conditions, the units must,
if necessary, be checked at least
yearly by a specialist to ensure
that they are in a condition that
is safe to use

Keep the units free of dust

and other debris

Only clean the units with a dry

or moistened cloth

Never subject to direct jets

of water
such as a high-pressure cleaner
etc.

Never use abrasive or solvent-

based cleaners

Use only suitable cleaners for

heavy contamination

Care and maintenance

All moving parts have a low-
maintenance permanent coat
of lubricant. The refrigerant system
is designed as a hermetically sealed
system and may only be repaired
by a specialist.

NOTE

Regular care and maintenance
is fundamental to a long
service life and fault-free
operation of the unit.

NOTE

Heavily contaminated dust
filters must be replaced with
new parts.
Only original replacement
parts may be used

NOTE

Installation work may only
be carried out by authorised
qualified technicians.
by authorised specialists.

B

C

A

ATTENTION

Check the inlet and outlet

grille and the dust filter for

contamination on a regular

basis.

!

ATTENTION

Before undertaking any
work on the units, the mains
plug must be removed from
the mains socket.

!