Troubleshooting

The units are manufactured
using state-of-the-art production
methods and tested several times
to verify their correct function.
However, if a functional fault
should occur, the unit should first
be checked in accordance with
the following list:

The unit does not start

Check the setting

of the operating switch.
The green control lamp should
illuminate

Check mains connection

230V/1~/50 Hz

Check mains plug and cable for

damage

Check the customer-provided

mains protection.
Minimum protection 10A

Check the level and correct

positioning of the condensate
container.
The front sealing flap must
be fully closed and locked

Check the function

of the microswitch

Check the setting

of the humidity switch
(accessories).
The pre-set value must be
lower than the relative humidity
inthe room.

Check the humidity switch

adapter for damage and correct
positioning

The unit runs but does not
form any condensate

Check the room temperature.

The operating range of the unit
is between 3°C and 32°C

Check the humidity of the air,

min. 40% RH required

Check the setting ofthe humidity

switch, set a lower humidity
value if necessary

Check the dust filter

forcontamination and clean
orreplace if necessary

Check the evaporator

and condenser fins for
contamination and clean
ifnecessary

Check the evaporator for ice

or rime formation If ice has
formed, check the functionality
of the automatic defrost
and the temperature sensor

Check whether or not

the evaporator temperature
is below room temperature
If this is not the case, check
the automatic defrost or room
temperature

The unit does not start

Check whether or not

the condensate container
is inserted correctly and that
the front sealing flap is locked

Check whether or not mains

power is available

4. Clean the condenser fins

by blowing, with suction
or using a smooth brush.

5. Exercise extreme caution when

cleaning the condenser. The fine
aluminium fins bend very easily.

6. Never subject to sharp jets

of water (high-pressure
cleaners).

7. Clean the evaporator fins, for

example with a lukewarm soap
solution (or similar).

8. Rinse with clean water

to remove any remaining soap.

9. Clean the internal surfaces

of the entire unit as well
as the fan blade.

10. Once cleaning has been

completed, the unit should
be dried with care.
Take particular care with
electrical components!

11. Re-install all dismantled

components in reverse order.

12. Carry out a unit function check

and electrical safety check.

NOTE

If the unit fails to function
correctly after the checks have
been carried out, an authorised
specialist must be informed.

ATTENTION

Work on the refrigerant
system and on the electrical
equipment must only
be conducted by a specially-
authorised specialist.

!

ATTENTION

An electrical safety check must
be carried out in accordance
with VDE 0701 after any work
on the units.

!