Installation – Desa VP30BT User Manual

Page 11

Advertising
background image

www.desatech.com

107886-01J

11

4. If installing bottom mounting screws into

hollow or solid wall, install wall anchors.

Follow steps 1 through 4 under Attaching To

Wall Anchor Method, page 10

If installing bottom mounting screw into wall

stud, drill holes at marked locations using

9/64" drill bit.

5. Replace heater onto mounting bracket.
6. Place spacers between bottom mounting holes

and wall anchor or drilled hole.

7. Hold spacer in place with one hand. With other

hand, insert mounting screw through bottom

mounting hole and spacer. Place tip of screw

in opening of wall anchor or drilled hole.

8. Tighten both screws until heater is firmly

secured to wall. Do not over tighten.

Note:

Do not replace front panel at this time.

Replace front panel after making gas connec-

tions and checking for leaks (see pages 11

through 13).

MOUNTING HEATER TO FLOOR

Mounting Base Feet to Heater
1. Lay heater cabinet on its back on a table with

the heater bottom overhanging the table edge.

2. Align holes in base foot with mounting holes

on bottom of cabinet (see Figure 13).

3. Secure base foot to heater using sheet metal

screws.

4. Repeat for other side.

INSTALLATION

Continued

Figure 13 - Installing Base Feet

Sheet Metal Screw

Base Foot

Wood
Screw

Mounting Base Feet to Floor (Where
required by local code)
1. Remove front cover (see Removing Front

Panel of Heater, page 9).

2. Position heater with base feet in desired loca-

tion. Mark holes for drilling. Remove heater

with base.

3. For carpeted floors, make a small cut with a

sharp knife at marked locations prior to drill-

ing. If mounting base to a wood floor, drill 1/8

inch diameter hole, 3/4 inch deep. (Do not use

anchors in wood floors).

If mounting base to a concrete floor, drill

with 1/4 inch diameter concrete drill bit, 1

3

/

8

inches into floor. Insert anchors completely

into holes.

4. Reposition heater with base feet over holes.

Secure base to floor with wood screws. See

Figure 13.

CONNECTING TO GAS SUPPLY

WARNING: This appliance

requires a 3/8" NPT (National

Pipe Thread) inlet connection to

the pressure regulator.

WARNING: A qualified service

person must connect heater to gas

supply. Follow all local codes.

WARNING: For natural gas,

never connect heater to private (non-

utility) gas wells. This gas is com-

monly known as wellhead gas.

IMPORTANT:

For natural gas, check gas line

pressure before connecting heater to gas line. Gas

line pressure must be no greater than 10.5 inches of

water. If gas line pressure is higher, heater regula-

tor damage could occur.

CAUTION: For propane/LP

gas, never connect heater directly

to the propane/LP supply. This

heater requires an external regu-

lator (not supplied). Install the

external regulator between the

heater and propane/LP supply.

For propane/LP gas, the installer must supply an

external regulator. The external regulator will

reduce incoming gas pressure. You must reduce

incoming gas pressure to between 11 and 14 inches

of water. If you do not reduce incoming gas pres-

sure, heater regulator damage could occur. Install

the external regulator with the vent pointing down

as shown in Figure 14, page 12. Pointing the vent

down protects it from freezing rain or sleet.