BURNER FLAME PATTERN

WARNING: If yellow tipping

occurs, your heater could pro-

duce increased levels of carbon

monoxide.

NOTICE: Do not mistake orange

flames with yellow tipping. Dirt

or other fine particles enter the

heater and burn causing brief

patches of orange flame.

OPERATING HEATER

Continued

8. Turn control knob counterclockwise

to desired heating level. The main burner

should light. Set control knob to any heat

level between 1 and 5.

CAUTION: Do not try to ad-

just heating levels by using the

equipment shutoff valve.

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1. Turn control knob clockwise

to the

OFF position.

2. Turn off all electric power to the appliance

if service is to be performed.

Shutting Off Burner Only (pilot stays lit)

Turn control knob clockwise

to the

PILOT position.

THERMOSTAT

CONTROL OPERATION

The thermostatic control used on these models

differs from standard thermostats. Standard

thermostats simply turn on and off the burner.

The thermostat used on this heater senses the

room temperature. The thermostat adjusts the

amount of gas flow to the burner. This increases

or decreases the burner flame height. At times the

room may exceed the set temperature. If so, the

burner will shut off. The burner will cycle back

on when room temperature drops below the set

temperature. The control knob can be set to any

heat level between 1 and 5. Selecting the 5 setting

will cause the burner to remain fully on without

modulating down in most cases.
Note:

The thermostat sensing bulb measures

the temperature of air near the heater cabinet.

This may not always agree with room tem-

perature (depending on housing construction,

installation location, room size, open air tem-

peratures, etc.). Frequent use of your heater will

let you determine your own comfort levels.

MANUAL LIGHTING

PROCEDURE

1. Remove front panel (see Figure 7, page 9).

2. Follow steps 1 through 5 under Lighting

Instructions, page 14.

3. With control knob pressed in, strike match.

Hold match to pilot until pilot lights.

4. Keep control knob pressed in for 30 seconds

after lighting pilot. After 30 seconds, release

control knob. Now follow step 8, under

Lighting Instructions, pages 14 and 15.

5. Replace front panel.

INSPECTING HEATER

Check pilot flame pattern and burner flame pat-

tern often.

PILOT FLAME PATTERN

Figure 21 shows a correct pilot flame pattern. Figure

22 shows an incorrect pilot flame pattern. The incor-

rect pilot flame is not touching the thermocouple.

This will cause the thermocouple to cool. When the

thermocouple cools, the heater will shut down.
If pilot flame pattern is incorrect, as shown in

Figure 22
• turn heater off (see To Turn Off Gas to Appli-

ance)

• see Troubleshooting, page 18
Note:

The pilot flame on natural gas units will

have a slight curve, but flame should be blue and

Figure 22 - Incorrect Pilot Flame Pattern

Figure 21 - Correct Pilot Flame Pattern

Thermocouple

Pilot Burner

Pilot Burner

Thermocouple

Blue Flame

Yellow Flame