TROUBLESHOOTING

Continued

POSSIBLE CAUSE

1. Gas leak. See Warning

statement on page 21

2. Control valve defective

1. Foreign matter between con-

trol valve and burner

2. Gas leak. See Warning

statement on page 21

1. Not enough combustion/ven-

tilation air

OBSERVED PROBLEM

Gas odor even when control knob

is in OFF position

Gas odor during combustion

Moisture/condensation noticed

on windows

REMEDY

1. Locate and correct all leaks

(see Checking Gas Connec-

tions, page 12)

2. Replace control valve

1. Take apart gas tubing and

remove foreign matter

2. Locate and correct all leaks

(see Checking Gas Connec-

tions, page 12)

1. Refer to Air for Combustion

and Ventilation requirements

(page 5)

REPLACEMENT PARTS

Note:

Use only original replacement parts. This

will protect your warranty coverage for parts

replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If

they canʼt supply original replacement part(s),

call DESA Heating Productsʼ Technical Service

Department at 1-866-672-6040.
When calling DESA Heating Products, have

ready
• your name
• your address
• model and serial numbers of your heater
• how heater was malfunctioning
• type of gas used (propane/LP or natural gas)
• purchase date
Usually, we will ask you to return the part to the

factory.

PARTS NOT UNDER WARRANTY

Contact authorized dealers of this product. If they

canʼt supply original replacement part(s), call

DESA Heating Products at 1-866-672-6040 for

referral information.
When calling DESA Heating Products, have

ready
• model number of your heater
• the replacement part number

ACCESSORIES

Purchase these heater accessories from your local

dealer. If they can not supply these accessories,

call DESA Heating Products at 1-866-672-6040

for referral information. You can also write to the

address listed on the back page of this manual.

EQUIPMENT SHUTOFF VALVE
GA5010

For all models. Equipment shutoff valve with

1/8" NPT tap.

FAN KITS - GA3250T

For all models. Provides better heat distribution.

Makes heater more efficient. Complete installation

and operating instructions included.
Thermostatically-controlled, blower turns itself on

and off as required.

ELECTRONIC IGNITOR KIT - GA435
Not Shown

For all piezo ignitor models. Provides easier

lighting of the pilot.

Advertising