REMKO Multi-talent Plus User Manual

Page 19

Advertising
background image

Factory setting

Designation

Day

Time

Operating mode / description

Heating circuit 1

prog 1

Mo.-Fr.

Mo.-Su.

Sa.+Su.

06:00-22:00
06:00-22:00
07:00-23:00

Automatic 1

Heating circuit 1

prog 2

Mo.-Fr.

Mo.-Su.

Sa.+Su.

06:00-08:00, 16:00-22:00
06:00-08:00, 16:00-22:00

07:00-23:00

Automatic 2

Heating circuit 2

prog 1

Mo.-Fr.

Mo.-Su.

Sa.+Su.

06:00-22:00
06:00-22:00
07:00-23:00

Automatic 1

Heating circuit 2

prog 2

Mo.-Fr.

Mo.-Su.

Sa.+Su.

06:00-08:00, 16:00-22:00
06:00-08:00, 16:00-22:00

07:00-23:00

Automatic 2

Hot water

Mo.-Fr.

Mo.-Su.

Sa.+Su.

05:00-21:00
05:00-21:00
06:00-22:00

Automatic 1+2

Circulation pro-

gram

Mo.-Fr.

Mo.-Su.

Sa.+Su.

05:00-21:00
05:00-21:00
06:00-22:00

Automatic 1+2

WE 1-4 enable

Mo.-Fr.

Mo.-Su.

Sa.+Su.

00:00-24:00
00:00-24:00
00:00-24:00

The heating appliances can only be put into
operation in the enabled times set here.
(A demand for heat from a user or tank must
also exist for a heating appliance to operate).

S-Kick enable

Mo.-Su.

07:00-22:00

Enable time for the solar kick functions
(see specialist

solar MF).

PU night charging

Mo.-Su.

00:00-05:00

Conventional heat pumps are blocked during
the enable time set here. In this time period,
the buffer tank is only warmed by the heat
pump to the set temperature (see specialist

heat pump

Min T-PU WE).

PU night charging should not be enabled in
the heating and hot water time periods.

All time programmes can be set here.

Level 4 - TIME PROGRAMME - Description of parameters and settings

19