Seaward ARE 1557 User Manual

Page 11

Advertising
background image

ERT1557

Operating Instructions

- 11 -

4 Unit Description
The ERT 1557 is a hand held, earth resistance tester.
Tests are selected using the rotary switch.

4.1 Identifying parts of the unit

The numbering below refers to fig. 1 and fig. 2.

1. LCD Display

2. Function keys F1, F2, F3 and F4
3. TEST key

4. Rotary Switch
5. Test lead inputs Es, E, S and H
6. Current clamp input

7. Current clamp input
8. Data port

4.2 LCD display messages

Display

Meaning

>50k

W

Result is above the measuring range
for 2 and 3 point earth resistance

>2k

W

Result is above the measuring range
for current clamp earth resistance

>1999k

Wm Result is above the measuring range

for earth resistivity

More than 20Veff noise present. The

ERT 1557 is unable to make a
measurement.

RP

The resistance between the Potential

test spike and earth is too high.

RC

The resistance between the Current

test spike and earth is too high.

No

Request cannot be executed e.g.
result cannot be stored in a particular

memory location or particular result
cannot be recalled.

001

Memory location identifier

0.0.1

Measurement location identifier

Alternate

E-ES/ES-S

The ES and E connections are

reversed. Correct the problem to
proceed

Stor

Storing result

RCL

Recalling result

Prt

Downloading data mode

Advertising