2
- Acquisition:
From host comport / From SDB: Select the origin of the input data.
If the input data comes from the host comport, the followings parameters define the
signal to save into the SMT351 memory:
Sampling Frequency: Set the sampling frequency in MHz.
Signal Frequency: Set the signal frequency in MHz.
Signal selection: Select the type of signal to write to the SMT351 memory.
Address: Set the address for the memory from where to read.
Bytes to acquire: Set the size of the acquisition in bytes.
File to save data: Set the file to which the data should be written.
Acquire data: Press this button to start an data acquisition.
4.1.3
SMT381
This section explains how to use the "Configure FPGA-only module" user interface.
For more information on how to set the parameters please look at the
SMT381 user
manual
.