Installation – Desa CD42M-A2 User Manual

Page 10

Advertising
background image

www.desatech.com

111916-01F

10

In conformance with local codes, route a 1/2"

NPT gas line towards the appliance coming in

from either the left or right side of the fireplace

(see Figure 13).
Install a sediment trap between the incoming gas

line and the gas control box (see Figure 14). The

sediment trap should extend down a minimum of

3" (7.62 cm) beyond the center of the pipe.
When routing gas line through conduit sleeve,

make sure to repack insulation to fill gaps between

gas line and conduit sleeve. Compounds used on

threaded joints of gas piping shall be resistant to

the action of propane or natural gas. Compounds

should be applied lightly to ensure excess sealant

does not enter the gas line.
Complete your gas line installation by connect-

ing the incoming gas line to the flexible gas

line. Secure tightly with a wrench but do not

over-tighten.

WARNING: All gas piping

and connections must be tested

for leaks after the installation is

completed.
Never use an open flame to

check for a leak. After ensuring

that the gas valve is open ap-

ply commercial leak detection

fluid to all gas joints. Bubbles

forming show a leak. Correct all

leaks at once.
Do not operate any appliance if

a leak is detected.

INSTALLATION

Continued

Figure 13 - Gas Line Routing

Gas Routing
(Right Side Not Shown)

Side of
Fireplace

Front Face

Figure 14 - Sediment Trap

Sediment Trap
(Not Supplied)

Incoming 1/2" Gas Line
Permitted By Local Codes

3" Min.
(7.6 cm)

PILOT ADJUSTMENT

The pilot or electrode assembly is factory preset

for the proper flame height. Alterations to these

settings may have occurred during shipping and

handling. If this is the case, some minor readjust-

ments may be necessary and should be done by a

qualified service technician. The proper settings

for the thermopile height should be at a distance

of 3/8" (.95 cm) to 1/2" (1.27 cm) from the pilot

flame as shown in Figure 15.

Figure 15 - Pilot Assembly

1/8"

(0.3cm)

3/8" - 1/2"

(.95cm-1.3cm)

REMOVING GLASS PANEL

CAUTION: Before you pro-

ceed, make sure your gas control

valve is in the OFF position.

1. To remove louvers, pull both spring latches

(located in each end of louver) toward center

of appliance at the same time until disengaged

from locating holes. Repeat for bottom end

spring latches (see Figure 16, page 11).

2. Remove screen rod by removing rod loop

from glass door center bracket. Slide screen

rod either to the left or right of fireplace until

one end is free to completely remove screen

from fireplace.