Burner flame adjustment, Installation – Desa CD42M-A2 User Manual

Page 13

Advertising
background image

www.desatech.com

111916-01F

13

Lava Rock and Ember Material
1. For all models, place lava rock along sides and

front of firebox bottom in areas that are visible. It

is not necessary to use all lava rock provided.

NOTICE: Do not put lava rock

on or under burner. Placing

lava rock on burner could cause

performance problems.

2. Pull ember material apart into pieces no larger

than a dime. Place loosely and directly onto

exposed section of front burner and along space

between burner and grate prongs. These will cre-

ate glowing ember appearance as flame touches

ember material. Do not block air slots by using

too much ember material in one area. It is not

necessary to use all ember material provided.

3. When lava rock and ember material are in

place, close and latch glass door and secure

louvers in place.

WARNING: The glass door

must be securely in place before

operating fireplace. Do not oper-

ate fireplace if glass is missing

or broken.

DECORATIVE FACING

Any noncombustible material may be used as fac-

ing (glass, tile, brick, etc.) as long as the proper

clearances are observed (see Clearances to Com-

bustibles, page 4). Louvered openings must not

be obstructed and upper and lower panels must

remain accessible for service. Use only heat-re-

sistant, noncombustible mortar or adhesive when

securing decorative facing materials.

FACE EXTENSION FOR MODEL
CD32M ONLY

Model CD32M comes equipped with a front face

extension. The front face extension would add

3

1

/

2

" to the width and 3/4" to the height of the

fireplace face.
To install face extension:
1. Remove existing screws from front face as-

sembly as shown in Figure 29.

2. Align holes on top face extension with holes on

top side of front face assembly and secure with

screws previously removed (see Figure 29).

INSTALLATION

Continued

3. Align holes on right face extension with holes

on right side of front face assembly and secure

with screws previously removed (see Figure

29). Do the same for left side.

4. Secure top face extension with left and right

face extensions with two sheet metal screws

(see Figure 29).

Figure 29 - Front Face Extension, Model

CD32M Only

BURNER FLAME

ADJUSTMENT

The burner flame adjustment (shutter opening) has

been factory preset (for natural gas) to the proper

air-to-gas ratio. This ratio results in an even, clean

burning flame across the burner (see Figure 30).

Figure 30 - Burner Flame Patterns

CORRECT

INCORRECT
CLOSE
SHUTTER

INCORRECT
OPEN
SHUTTER

Short, Sharp, Blowing Flame

Long, Blue Flame with Yellow Tips

Long, Uneven, Yellow Flame

Side Face