INSTALLATION

Continued

ELECTRICAL HOOKUP AND
REMOTE RECEIVER DIAGRAM

An outlet box with two receptacles (see Figure 9) has

been supplied for your convenience and is located

inside on the lower right side of the fireplace.
The remote control receiver is factory wired and

connected to the convertible gas valve as shown

in Figure 10.

Figure 9 - Duplex Outlet

Three-prong Plug

Figure 10 - Remote Control Receiver

Outlet Box

Remote
Control
Receiver

Convertible
Gas Valve

GAS SUPPLY TESTING

NOTICE: This section is in-

tended as a guide for qualified

technicians installing gas to the

appliance.

WARNING: Do not connect

appliance before pressure test-

ing gas piping. Damage to gas

valve may result and an unsafe

condition may be created.

The appliance and its individual shutoff valve must

be disconnected from the gas supply piping system

during any pressure testing of that system at test

pressures in excess of 1/2 psig (3.5 kPa).

The appliance must be isolated from the gas sup-

ply piping system by closing its individual shutoff

valve during any pressure testing of the gas supply

piping system at test pressures equal to or less than

1/2 psig (3.5 kPa).
The gas control valve is secured underneath the

firebox. Two 1/8" ports are provided on the gas

control valve for pressure test gauge connections

(see Figure 11).

Figure 11 - Gas Control Valve

ON/OFF
Knob

Pilot Adjustment

Inlet
Pressure Outlet

Pressure

Flame
Adjustment Knob

Pilot Gas Line
Do Not Kink

To Pilot
Burner

To Main
Burner

GAS LINE HOOK-UP

WARNING: Gas line hook-

up should be done by your gas

supplier or a qualified service

person.

WARNING: Before you pro-

ceed, make sure your gas supply

is OFF.

An equipment shutoff valve has been included in

the fireplace's gas supply system. However, con-

sider installing an extra shutoff valve outside the

applianceʼs enclosure (check local codes), where

it can be accessed more conveniently with a key

through a wall as shown in Figure 12.

Figure 12- Typical Exterior Wall Gas

Shutoff Installation

Key

Extension

Shutoff
Valve