Installation – Desa CD42M-A2 User Manual

Page 8

Advertising
background image

www.desatech.com

111916-01F

8

Figure 7 - Vent Termination (Horizontal)

Direct-Vent Pipe
CD32M and
CD36M-A
4

1

/

4

" Inner and

7

1

/

4

" Outer

CD42M-A
5" Inner and 8"
Outer

Wall Firestop

Maintain 1"
Minimum
Air Space
Around Outer
Pipe when
Penetrating a
Wall

Horizontal
Termination
(Vent Cap)

Screws

Exterior Wall
with Vinyl
Siding

Deflector
Shield

Minimum Pipe
Overlap 1

1

/

4

"

Siding Standoff
(Optional)

Framed Openings
CD32M and
CD36M-A
10" x 10"
CD42M-A
10

3

/

4

" x 10

3

/

4

"

6. For vertical installation, a vertical termination is

available. Also for vertical venting application,

install vertical flue restrictor into inner collar of

fireplace as shown in Figure 6, page 7.

When installing a length of pipe for vertical

termination that is over 3 ft., support the pipe

every 3 ft. using metal wall straps. Vertical to

horizontal pipe must be kept at a 1 ft. to 4 ft. ratio

with a maximum run of no more than 20 ft.

If an offset is necessary in the attic to avoid

obstruction, it is important to support the

vent pipe every 3 ft. to avoid excessive

stress on the elbows and possible separation

(see Figure 8).

Clearances must be maintained between the roof

and the termination. Refer to chart below.

Roof Pitch

Minimum Height

Above Roof

Flat - 7/12

1 ft. (30.48 cm)

7/12 - 8/12

1

1

/

2

ft. (45.72 cm)

8/12 - 9/12

2 ft (60.96 cm)

9/12 - 10/12

2

1

/

2

ft (76.20 cm)

10/12 - 11/12

4 ft (121.92 cm)

11/12 - 14/12

5 ft (152.40 cm)

14/12 - 16/12

6 ft (182.88 cm)

16/12 - 18/12

7 ft (213.36 cm)

18/12 - 20/12

7

1

/

2

ft (228.60 cm)

20/12 - 21/12

8 ft (243.84 cm)

INSTALLATION

Continued

Figure 8 - Vertical Termination with

Offset and Wall Strap

Wall Strap

Roof
Flashing

45° Elbows

Ceiling Firestop