Operating fireplace, Burner flame adjustment – Desa CD42M-A2 User Manual

Page 14

Advertising
background image

www.desatech.com

111916-01F

14

If adjustment is necessary, you can restore the

proper flame setting by loosening the air shutter

screw and rotating the air shutter until proper

setting is achieved (see Figure 31). The correct

shutter openings are as follows:

BURNER FLAME

ADJUSTMENT

Continued

Tube Burner

Pan Burner

Model

Natural Propane/

LP

Natural Propane/

LP

CD32M

0.188"

Max.

CD36M-A 0.188"

Max

CD42M-A 0.188"

0.313"

0.188"

0.500"

WARNING: Improper installa-

tion, adjustment, alteration, ser-

vice or maintenance can cause

injury or property damage. Refer

to this manual for assistance.

Consult a qualified installer for

additional information.

Figure 31 - Air Shutter Adjustments

Manifold

Air Shutter
Opening

Firebox
Bottom

Burner
Gas Line

Burner Pan

Burner
Tube

Adjustment Screw

Adjustment
Screw

Manifold

Air Shutter
Opening

Burner
Gas Line

Firebox
Bottom

OPERATING FIREPLACE

OPERATION GUIDELINES

• When used for the first time, the fireplace may

emit a slight odor for about 16 to 24 hours. This

is normal and is due to the “curing” of the logs

and the “burn-in” of internal paint and lubricant

used in the manufacturing process.

• Keep compartments, logs, burners and area sur-

rounding logs clean by vacuuming and brushing

at least twice a year or as necessary.

• Turn off gas and remote switch before servicing

appliance. Any safety screen or guard removed

for servicing the fireplace must be replaced

prior to operation.

• Have a qualified agency periodically inspect

vent system at the start of each heating season

for any obstruction which will hinder its normal

operation. Never obstruct the flow of combus-

tion and ventilation air. Keep the front of the

fireplace clear of all obstacles and materials.

FOR YOUR SAFETY

READ BEFORE LIGHTING

WARNING: If you do not fol-

low these instructions exactly,

a fire or explosion may result

causing property damage, per-

sonal injury or loss of life.

A. This appliance has a pilot which must be

lighted by hand. When lighting the pilot,

follow these instructions exactly.

B. BEFORE LIGHTING smell all around the

appliance area for gas. Be sure to smell next

to the floor because some gas is heavier than

air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.

• Do not touch any electric switch; do not

use any phone in your building.

• Immediately call your gas supplier from

a neighborʼs phone. Follow the gas

supplierʼs instructions.

• If you cannot reach your gas supplier, call

the fire department.

C. Use only your hand to push in control knob.

Never use tools. If the knob will not push

in or slide by hand, donʼt try to repair it,

call a qualified service technician. Force

or attempted repair may result in a fire or

explosion.