TROUBLESHOOTING

WARNING: Turn off heater and let cool before servicing. Only a

qualified service person should service and repair heater.

WARNING: Turn off heater and let cool before servicing. Only a

qualified service person should service and repair heater.

OBSERVED PROBLEM

Pilot will not stay lit

Pilot lit but no flame on burner

Frequent pilot outage

POSSIBLE CAUSE

1. Defective thermocouple

1. Remote or wires defective

2. Thermopile not generating

sufficient milivoltage

3. Plugged burner orifice

1. Pilot flame may be too low

or blowing (high) causing

safety pilot to “drop out”

REMEDY

1. Check pilot flame. It must

impinge on thermocouple

2. Clean or adjust pilot for maxi-

mum flame impingement on

thermocouple

3. Ensure the connection be-

tween valve and thermocouple

are tight and secure

4. Check thermocouple with

millivolt meter. Take reading

at thermocouple terminals of

gas valve with remote control

off. It should read 18 millivolts

minimum. Replace faulty ther-

mocouple if reading is below

specified minimum

1. Check remote wires for proper

connections. Place jumper

wire across terminals at re-

mote control. If burner comes

on, replace remote. If okay,

place jumper wire across

remote control at valve. If

burner comes on, wires are

faulty or connections are bad

2. Check thermopile with mil-

livolt meter. Take reading at

thermopile terminals of gas

valve with remote control off.

It should read 325 millivolts

minimum. Replace thermopile

if reading is below specified

minimum

3. Check burner orifice for stop-

page and remove

1. Clean and/or adjust pilot flame

for maximum flame impinge-

ment on thermocouple