SPECIFICATIONS

CD32M

CD36M-A

CD42M-A

Gas Rate (Natural)

12,000/
18,000 Btu/hr

15,000/
22,000 Btu/hr

25,000/
35,000 Btu/hr

Gas Rate (Propane/LP)

11,000/
17,000 Btu/hr

14,000/
20,000 Btu/hr

23,000/
33,000 Btu/hr

Ignition

Piezo

Piezo

Piezo

Natural Gas Manifold Pressure

3.5" w.c.

3.5" w.c.

3.5"w.c.

Propane/LP Manifold Pressure

10" w.c.

10" w.c.

10" w.c.

Minimum Inlet Supply Pressure

4.5" w.c.

4.5" w.c.

4.5" w.c.

WIRING DIAGRAM

Thermocouple

Incoming

Main

Gas

Supply

Piezo Ignitor

Control

Valve

Electrical Rating:

120v, 60Hz, 0.7A

Optional Wiring Diagram

For Fan Kit

Pilot

TH

TP

TPTH

Thermopile

Piezo Ignitor

Do Not

Connect

To 120V

(Remote Switch

Field Supplied)

Safety Microswitch for

Models CD32M-2, CD36M-A2

and CD42M-A2 Only

Pilot

Gas Line

Wireway

GND

BLK
WHT
GRN

Incoming

120V AC

(Fuse Box

or

Breaker)

Connectors

(Not Supplied)

Field Wire

N.O.SW

Advertising