INTRODUCTION

WARNING: This product con-

tains and/or generates chemicals

known to the State of California

to cause cancer or birth defects

or other reproductive harm.

Models CD32M series, CD36M-A series and

CD42M-A series are heat circulating grav-

ity direct-vent fireplaces with sealed combustion

chamber. These fireplaces use millivolt gas control

valve and millivolt ignition system.
These fireplaces are convertible with the standard

setup as natural gas. Conversion may be performed

by the O.E.M. mobile home builder or by a quali-

fied service person on-site. If you are uncertain as

to what gas your unit is equipped for, please check

the rating plate located inside of the appliance

opening or consult your mobile home supplier or

your local distributor of DESA/Vexar products.

NOTICE: Check local building

codes for area requirements be-

fore installing this appliance.

BEFORE YOU BEGIN

Before beginning the installation of your appli-

ance, read these instructions through completely.
This DESA/Vexar fireplace and its components are

safe when installed according to this installation

manual and operated as recommended. Unless

you use DESA/Vexar components designed and

tested for this fireplace system,

YOU MAY CAUSE

A SAFETY HAZARD!

The DESA/Vexar warranty will be voided by, and

DESA/Vexar disclaims any responsibility for the

following actions:
A) Modification to the fireplace, components,

doors, blower, fans or vent system.

B) Use of any component part not manufactured or

approved by DESA/Vexar in combination with

a DESA/Vexar fireplace system.

Proper installation is the most important step in

ensuring safe and continuous operation of the

fireplace. Consult the local building codes as to the

particular requirements concerned with the instal-

lation of all factory built fireplaces. This fireplace,

when installed, must be electrically grounded in

accordance with local codes or in the absence of

local codes, with the National Electrical Code,

ANSI/NFPA 70 or the Canadian Electrical Code,

CSA C22.1.

The installation must conform with local codes or,

in the absence of local codes, with the National Fuel

Gas Code, ANSI Z223.1 or the Canadian Installa-

tion Code, CAN/CGA B149. This appliance com-

plies with ANSI Z21.88-1998 and CSA 2.33-M98

as a VENTED GAS FIREPLACE HEATER.

SELECTING LOCATION

To determine the safest and most efficient loca-

tion for your fireplace, consider the following

guidelines:
1. The location must allow for proper clearances

(see Figure 1).

2. Consider a location where the fireplace would

not be affected by drafts, air conditioning

ducts, windows or doors.

3. A location that avoids the cutting of joists or roof

rafters makes ventilation installation easier.

In selecting a location, the following precautions

must be observed:
• Do not connect this appliance to a chimney

system used for solid fuel burning fireplace.

• Due to high temperatures, do not locate this

appliance in high traffic areas or near furniture

and draperies.

• Never obstruct the openings of the appliance

or flow of ventilation air. Keep the control

compartments accessible.

Figure 1 - Common Fireplace Locations

FULL

PROJECTION

CORNER

INSTALLATION

FLUSH

INSTALLATION

Flush installation is recommended where living

space is limited.

Projected installation may be ideal for a new

addition to an existing finished wall.

Corner installation makes use of a space that may

not normally be used and provides a wider and

more efficient range for radiant heat transfer.