Verilink 2048 (34-00179) Product Manual User Manual
Page 31

Terminal Operation
4 -11
2048 PMU/NTU
4.7.1
General Functions
Set Time: The current time may be entered in this field
using the 24 -hour HH:MM: SS format. For example, 3:45
AM is entered as ‘
0345
’ and 3:45 PM is entered as ‘
1545
’.
Set Date: The current date may be entered in this field
using the MM:DD:YY format. For example, July 4, 1994 is
entered as ‘
070494
’.
NOTE: The time and date can be set at the far end, but
not displayed.
New Password: This field allows entry of a password of up
to 10 characters. An empty string (carriage return only) may
be entered to disable the password feature. After <return> is
pressed, the new password is activated and is no longer visi-
ble. Therefore, type carefully when entering a new password
and verify before pressing <return>. When the Terminal
Interface is exited and later reactivated, this password must
be entered exactly to gain access. If the wrong password is
entered, the following message appears:
Incorrect Password; Please Enter Again
NOTE: Do not exit the Terminal Interface program
until the password procedure is fully understood. If a
password has been specified, it must be typed exactly to
reenter the program.
Maintenance Reset: This field will clear all user selectable
parameters, performance registers, passwords, and alarms.
All alarm threshold parameters will be reset to default val-
ues. The unit reloads start-up configuration settings from
the source specified by configuration switch S4 (refer to the
‘Installation’ chapter). Pressing <return> on this field brings
up the following warning:
DELETE ALL DATA AND RESTART UNIT?
(NO!)
(YES)
To exit this screen without performing the reset function,
press <return> on
(NO)
. To proceed with the reset function,
move the cursor to
(YES)
and press <return>. A mainte-
nance reset may also be performed using Switch S6-2 (refer
to Section 2.5.7 on page 2-4).
4.7.2
COA Parameters
The following fields pertain to the call on alarm (COA)
parameters.
Alarm Notification: This field controls remote alarm
reporting. The choices are:
[
OFF
] - Disables alarm reporting.
[
DIRECT
] - Sends reports to a printer or terminal con-
nected directly to the supervisory port.
[
DIAL
] - Sends reports through an attached ‘AT’ com-
mand set compatible modem connected to the ‘SUPV’
serial port, which must dial out to a remote modem. The
message format is described in the ‘Element ID’ field.
[
DIAL
NMS
] - Sends reports through a modem to an
EM8000 network manager workstation.
Primary Phone#, Secondary Phone#: These fields are
ASCII strings for the primary and secondary call on alarm
(COA) phone numbers used in the [
DIAL
] and [
DIAL
NMS
]
modes. The strings must be compatible with the standard
2048 PMU x.xx/x.xx
2048 PMU Date
MM/DD/YY
2048 PMU x.xx/x.xx
(Unit Address: xxx)
Time HH:MM:SS
---------------------------------- UTILITIES
-----------------------------------
Element: [NEAR]
Set Time:
(14:10:13)
Set Date:
(05/12/93)
Alarm Notification:
[DIAL ]
Primary Phone#:
(1 (205) 555-1212 )
Secondary Phone#:
(9,,532-8853,,253 )
Element ID:
(Example PMU 2048 )
New Password:
( )
(MAINTENANCE RESET)
Screen 4-8
Utilities