Chapter 5 MCC system.cfg Configuration File
Administration Guide
101
Unit Section
The unit section defines a unit device for a CPU. The unit section name
determines the name of the unit icon.
Names must be eight characters in length or less.
Valid Keys
Table 23 lists the valid key requirements:
Key Required?
Quantity
Description
number Yes 1 The
unique
unit
number (logical unit
number). Specified in
hex.
address Yes 1 Specified
in
hex.
type Yes
1
Specified
in
hex.
channel Yes 1 Specified
in
hex.
startup_status
No
0 or 1
The initial color for
the unit icon. See
status.cfg: Status
Colors on page 53.
Table 23 Console Section, Unit Keys
Example
[unit DASD1]
number=1
address=320
type=3380
channel=1
[unit MT1]
number=2
address=330
type=3480
channel=1d