Westermo TD-36 User Manual

Page 14

Advertising
background image

14

6618-2202

* Railway installation close to the rails.

For a cable located within 3 m and connected to this port, the use of shielded cable is recommended, this is

to minimise the risk of interference. The cable shield should be properly connected (360°) to an earthing point

within 1 m of this port. This earthing point should have a low impedance connection to the conductive enclo-

sure of the apparatus cabinet, or similar, where the unit is built-in. This conductive enclosure should be con-

nected to the earthing system of an installation and may be directly connected to the protective earth.

RS-422/485
Electrical specification

EIA/TIA-485 ITU V.11
2-wire or 4-wire twisted pair

Data rate

300 bit/s – 115.2 kbit/s

Data format

7 or 8 data bits, Odd, even or none parity, 1 or 2 stop bits.
9-12 bit words

Protocol

Transparent

Retiming

Yes

Turn around time

<10 µs (half duplex)

Transmission range

≤ 1200 m, depending on data rate and cable type (EIA RS-485)

Settings

120 W termination and failsafe biasing 680 W

Protection

Installation Fault Tolerant (up to ±60 V)

Isolation to

Power port

3 kV

rms

50 Hz 1 min

PSTN Line

2 kV

rms

50 Hz 1 min

Leased Line

2 kV

rms

50 Hz 1 min

I/O

1.5 kV

rms

50 Hz 1 min

Galvanic connection to

RS-232

Connection

Detachable screw terminal

Connector size

0.2 – 2.5 mm

2

(AWG 24 – 12)

Shielded cable

Not required*

Miscellaneous

Do not connect RS-232 and RS-422/485 simultaneously

RS-232
Electrical specification

EIA/TIA-232

Data rate

300 bit/s – 115.2 kbit/s

Data format

7 or 8 data bits, Odd, even or none parity, 1 or 2 stop bits.
9-12 bit words

Protocol

Transparent

Retiming

Yes

Transmission range

Cable length ≤ 15 m

Isolation to

Power port

3 kV

rms

50 Hz 1 min

PSTN Line

2 kV

rms

50 Hz 1 min

Leased Line

2 kV

rms

50 Hz 1 min

I/O

1.5 kV

rms

50 Hz 1 min

Galvanic connection to

RS-485

Connection

9-pin D-sub female (DCE)
and Detachable screw terminal (DCE )

Connector size

Detachable screw terminal 0.2 – 2.5 mm

2

(AWG 24 – 12)

Shielded cable

Not required*

Miscellaneous

Do not connect RS-232 and RS-422/485 simultaneously