Westermo TD-36 User Manual

Page 34

Advertising
background image

34

6618-2202

TD-36 – Secure Call-back

The TD-36 is connected to a PLC which one want to restrict access to. The TD-36 can
support access control through the Secure Callback function. In this example password
and callback to a predefined number is chosen. The modem in the calling end is here
chosen to be a PSTN modem, but can be any of the PSTN, ISDN or GSM modem from
the Westermo product range.
The DTE serial speed between the PLC – TD-36 and TDW-33 – PC is assumed to be
9600 8N1 but can be chosen to fit the actual system requirement.

Configure the TD-36

PSTN

Network

AT&F

Set the unit to factory default

AT+IPR=9600

DTE baudrate 9600

AT+ICF=3,4

Character framing 8 data, 1 stop, parity none

ATS0=1

Auto answer after first ring

ATQ1E0&C1&K0&A1

Suitable for PLC communication

AT&W

Store default settings

AT*WCB=4

Callback enabled, Password and callback number stored
in one or more positions of wcbtab

AT*WCBTAB=1,”+4670428000”,
”n3Y9kA6otYZu8”

Define callback number 1
When password 1 is entered number +4670428000 will
be called

AT*WCBTIME=10

Define delay time between hangup an callback
The TD-36 will wait 10s after hangup to callback
to allow the analogue modem to hangup