Westermo TD-36 User Manual

Page 43

Advertising
background image

43

6618-2202

Configure the TD-36 485

AT&F

Set the unit to factory default

AT&W

Store default settings

AT*WIOP=10,50,2,3,1

Set I/O params
Min pulse time = 100 ms (10)
Pulse repetition = 500 ms (150)
Trig type = Pulsed trigged (2)
Pulse trig type = POS, pos edge (3)
Output type = output enabled (1)

AT*WIOL=1,2,5,0,0,”070428000”,
“Temp. high server
room”,”+4670500899”,1, “password”

Define SMS message on entry 1
Entry = 1 (1)
Service = SMS (2)Retry = NEXT_ALLWAYS(5)
Timeout = 0
Priority = 0
Data 1 = SMS receiver number (070428000)
Data 2 = SMS text (Temp. high server room)
Data 3 = Service center Adress (+4670500899)
Data 4 = SMS protocol UDP (1)

AT*WIOL=2,7,2,60,0,+4616480250

Define Transparent I/O on entry 2
Entry = 2 (2)
Service = TRANS (7)
Retry =RETRY_3 (2) ;Do 3 connection attempts
Timeout = 600s (60)
Priority = 0
Data 1 = Phone number of the remote IDW-90
(+4616480250)


Configure the IDW-90

S3:1,3,4 OFF S3:2 ON

V.110 configured for GSM

To make switch setting active the power must be cycled OFF -> ON.

Activate events – The sending modem

IO input pulsed with one puls

SMS message transferred and transparent IO established

Testing by simulating the event

AT*WIOT=1

Force sending of SMS-message at entry 1

AT*WIOT=2

Force the transparent I/O connection to be established.